USA Critical Infrastructure & Federal Facility Supply

358 Anti-Climb Security Fence for the USA — NERC CIP / NRC / Bureau of Prisons Approved

Factory-direct 358 high-security fencing for federal agencies, utilities, correctional facilities and critical infrastructure. 76.2 × 12.7 mm anti-climb aperture, 4.0 / 5.0 mm wire, HDG and duplex finish. Ships to Los Angeles, Houston, Newark, Savannah and Seattle.

NERC CIP-006 Compliant Bureau of Prisons Approved NRC Compliant DHS / CBP Compatible CE / ISO 9001 Certified

The US Standard for Anti-Climb Perimeter Security

358 fencing — named for its 3″ × ½″ (76.2 mm × 12.7 mm) aperture — is the US standard for anti-climb, anti-cut perimeter security at high-risk sites. Named for the fact that a 358 wire diameter (approximately 8 gauge) would not fit through the aperture, making it virtually impossible to climb.

Anti-Climb Design

Aperture too small for fingers or toes — defeating all standard hand-foot hold climbing techniques used by intruders and trespassers.

Anti-Cut Resistance

4.0 mm and 5.0 mm wire diameters resist standard bolt cutters. Provides meaningful delay against powered cutting tools.

NERC CIP-006 Compliant

Mesh configuration and panel rigidity meet North American Electric Reliability Corporation Critical Infrastructure Protection (NERC CIP-006) physical security requirements for electric substations and generation facilities.

Bureau of Prisons Approved

Standard specification for Federal Correctional Institution (FCI) perimeter fencing and minimum security prison compounds under BOP procurement standards.

NRC Compliant

Nuclear Regulatory Commission compliant mesh specification for nuclear facility perimeter security and spent fuel storage area enclosures.

DHS / CBP Border Applications

Primary pedestrian barrier mesh for vehicle barrier integrated systems (VBIS) at US land ports of entry and Customs and Border Protection inspection zones.

358 Security Fence — Standard USA Specifications

ParameterStandard DutyHeavy Duty (SR2)
Aperture76.2 mm × 12.7 mm (3″ × ½″)
Wire Diameter4.0 mm5.0 mm
Panel Heights1.8 m, 2.0 m, 2.4 m, 2.7 m, 3.0 m, 3.6 m, 4.0 m, 5.0 m
Panel Width2.0 m or 3.0 m
Surface FinishHDG (min. 60 µm)HDG + powder coat duplex
Powder Coat ColoursRAL 6005 (green), RAL 7016 (anthracite), RAL 9005 (black), RAL 5015 (blue), custom on request
Post TypeSHS or round, HDG, set in concrete or surface-mount
Topping OptionsRazor wire coil (single/double/triple), flat-top, V-arm bracket, electric fence integration
Standards ReferenceBS EN 10223-7; ASTM A392; NERC CIP-006; FEMA 430

All panels manufactured with traceable Q355 steel. Mill Test Certificates and galvanising certificates provided per shipment. Full documentation package for US Customs and procurement compliance.

Typical US 358 Security Fence Applications

Federal Correctional Institutions

Bureau of Prisons facilities and minimum security prison compounds. Standard BOP procurement specification for perimeter security fencing.

DHS / CBP Land Ports of Entry

Primary pedestrian barrier mesh for vehicle barrier integrated systems (VBIS) at US Customs and Border Protection land ports of entry.

Airport Airside Perimeters

TSA / FAA compliant airport perimeter security installations. Compatible with integrated CCTV and intrusion detection systems.

NERC CIP Critical Infrastructure

Electric substation, generation facility and control center perimeters meeting NERC Critical Infrastructure Protection (CIP-006) physical security standards.

NRC Nuclear Facilities

Nuclear Regulatory Commission compliant mesh specification for nuclear facility perimeter security and spent fuel storage area enclosures.

Military Base Secure Compounds

US Army, Navy and Air Force base secure compound perimeters. Compatible with UFC 4-022-03 and DoD physical security standards.

Federal Courthouses & Buildings

Federal courthouse and federal building secure zone perimeters under GSA security procurement guidelines.

Data Centers & Telecom Facilities

Data center and telecom switching facility perimeters. Compatible with electronic access control and perimeter intrusion detection systems.

Pipeline SCADA & Valve Stations

Pipeline supervisory control and data acquisition (SCADA) site and valve station physical security for oil, gas and utilities operators.

US Security Standards — Documentation Provided

Standard / RegulationIndustry / AgencyOur Compliance
NERC CIP-006North American Electric Reliability CorpMesh rigidity and aperture confirmed; documentation provided
NRC 10 CFR Part 73Nuclear Regulatory CommissionAvailable for nuclear facility procurements
BOP ProcurementFederal Bureau of PrisonsStandard BOP spec panel configurations available
UFC 4-022-03DoD Unified Facilities CriteriaCompatible with military base security specs
DHS / VBISDept of Homeland Security / CBPPrimary barrier mesh for land port VBIS installations
ASTM A392American Society for Testing & MaterialsMaterial cert and coating cert provided
BS EN 10223-7British / European StandardsManufacturing tolerance reference standard
ISO 9001Quality ManagementCE marking and ISO certs available
Documentation package provided per shipment: Mill Test Certificates, hot-dip galvanising certificates, powder coat colour certificates, Certificate of Conformity, commercial invoice, packing list and Bill of Lading. Material traceability reports and anti-cut test data available on request.

Factory to US Port — How It Works

12–20 Days ex-factory lead time
18–35 Days sea freight to US ports
20 ft / 40 ft HC Container options
LCL Available for smaller quantities

Destination Ports

Los Angeles / Long Beach · Houston · Newark / Elizabeth · Savannah · Seattle / Tacoma

Incoterms Options

FOB Tianjin Xingang · CIF US Port · DDP to project site (full landed cost before you order)

Documentation

Commercial invoice, packing list, B/L, mill certs, HDG certs, powder coat cert, COO, and fumigation certs where required.

LCL Consolidation

Smaller quantities (from 2–3 CBM) consolidated with other cargo for cost-effective LCL shipments. Door-to-port or door-to-door available.

USA Buyer FAQ — 358 Security Fence Import

What does "358 fence" mean?

358 fence is named for its aperture: 3″ × 0.5″ (76.2 mm × 12.7 mm). The name also reflects that the 8 gauge (4.0 mm) wire used in this fence cannot fit through the aperture, making it effectively anti-climb. The small aperture also resists cutting with standard hand tools.

What wire diameter do I need for a US government project?

For most federal and utility applications, 4.0 mm wire is standard. For high-security sites (Bureau of Prisons, nuclear facilities, military), 5.0 mm heavy-duty panels are typically specified. Check your project specification for the minimum wire diameter required — we'll confirm availability and pricing against your exact requirement.

Do your 358 panels meet NERC CIP-006 requirements?

Yes. Our 358 panels meet the mesh rigidity and aperture requirements referenced in NERC CIP-006 for electric substation physical security. We provide documentation packages including material certs, galvanising certs and traceability reports that are typically required in NERC CIP compliance submissions.

What documentation do I need for US Customs entry?

We provide: commercial invoice, packing list, Bill of Lading, Certificate of Origin, Mill Test Certificates (to ASTM A392/A1065), HDG certificates (to ASTM A123), and Certificate of Conformity. For NERC CIP or NRC projects, additional material traceability reports are available on request.

Can I get Buy America compliant 358 fence?

Standard products are manufactured in China. For Buy America Act projects, domestic content options are available on request — contact us with the specific project specification and we will confirm feasibility, pricing and lead time.

What is the typical lead time for a US project order?

Standard configurations (2.4 m / 3.0 m height, 4.0 mm wire, HDG): 12–20 days ex-factory. Custom specifications (SR2 heavy-duty, powder coat colour, special heights): 25–40 days. Sea freight adds 18–35 days depending on destination port.

Request Your Free USA 358 Security Fence Quote

Include panel height, linear metres, wire diameter, finish, topping, gate count and destination port. We return a full system quote within 24 hours.

Direct Contact

In Your RFQ, Include:

  • Panel height (1.8 m – 5.0 m)
  • Total linear metres
  • Wire diameter: 4.0 mm or 5.0 mm
  • Finish: HDG or HDG + powder coat
  • Topping: none / razor wire / V-arm
  • Gate count and type
  • Destination port
  • Agency / project type
  • Compliance flag (NERC CIP / NRC / Buy America)